Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Vacuum Muffle Furnace
Created with Pixso. SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere

SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere

Brand Name: Chitherm
Model Number: HWF160-10NH
MOQ: 1
Price: Negotiable
Delivery Time: Customized
Payment Terms: Customized
Detail Information
Place of Origin:
China
Range Of Applications:
Industrial
Type:
Electric Holding Furnace
Usage:
Ceramic Sintering
Fuel:
Electric
Atmosphere:
Vacuum/Nitrogen/Hydrogen
Effective Chamber Dimensions:
500*500*650mm(W*H*D)
Rated Temperature:
900°c
Maximum Temperature:
1000°c
Transport Package:
Wooden Packaging
Specification:
1650*1950*2000mm(W*H*D)
Trademark:
Chitherm
Origin:
China
HS Code:
8514101000
Supply Ability:
50 Sets/Year
Customization:
Available
Certification:
ISO
Place Style:
Vertical
Packaging Details:
Customized
Supply Ability:
Customized
Highlight:

SUS310S vertical muffle furnace

,

Vacuum Atmosphere vertical muffle furnace

,

SUS310S electric muffle furnace

Product Description
SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere
Product Attributes
Attribute Value
Range of Applications Industrial
Type Electric Holding Furnace
Usage Ceramic Sintering
Fuel Electric
Atmosphere Vacuum/Nitrogen/Hydrogen
Effective Chamber Dimensions 500*500*650mm(W*H*D)
Rated Temperature 900°c
Maximum Temperature 1000°c
Transport Package Wooden Packaging
Specification 1650*1950*2000mm(W*H*D)
Trademark Chitherm
Origin China
HS Code 8514101000
Supply Ability 50 Sets/Year
Customization Available
Certification ISO
Place Style Vertical
Product Description

Chitherm Hwf160-10nh Vacuum Atmosphere Tank Furnace for Temperature Processing ISO Certified and 1000°c Maximum Temperature

1. Equipment Name and Model:

HWF160-10NH Vacuum Atmosphere Tank Furnace

2. Technical Indicators and Basic Configuration
  • 2.1 Rated Temperature: 900°C;
  • 2.2 Maximum Temperature: 1000°C;
  • 2.3 Tank Material: SUS310S;
  • 2.4 Tank Dimensions: Φ750×900mm (d×D);
  • 2.5 Effective Size: 500×500×650mm (W×H×D);
  • 2.6 Material Loading Method: Stainless steel saggars, a total of 7 layers, 2 saggars per layer, 14 saggars in total;
  • 2.7 Cooling Method: Natural cooling;
  • 2.8 Heating Element: FEC ceramic fiber heater;
  • 2.9 Temperature Control Stability: ±1°C, with the function of PID parameter self-tuning;
  • 2.10 Temperature Uniformity: ±5°C (tested in an empty furnace at a constant temperature of 900°C for 1 hour), with a reserved detection port;
  • 2.11 Temperature Control Thermocouple: K graduation;
  • 2.12 Number of Temperature Control Points: 3 points;
  • 2.13 Number of Temperature Measuring Points: 1 point;
  • 2.14 Number of Temperature Control Segments: Default 9 segments;
  • 2.15 Sintering Atmosphere: Nitrogen, hydrogen or a mixture of nitrogen and hydrogen;
  • 2.16 Oxygen Content Detection: Equipped with an oxygen content analyzer that can be used under reducing atmosphere conditions;
  • 2.17 Waste Gas Treatment: The discharged hydrogen is ignited when passing through the ignition device;
  • 2.18 Alarm and Protection: Sound and light alarm protection for over-temperature, thermocouple breakage, low air pressure, low water pressure, ignition, motor under-phase and reverse-phase, unqualified vacuum degree, etc., and it has the function of power-off protection for over-temperature alarm;
  • 2.19 Design Power: 40kW;
  • 2.20 Typical Heat Preservation Power of the Empty Furnace: ≤25kW;
  • 2.21 Heating Rate: ≤5°C/min;
  • 2.22 Surface Temperature Rise: <35°C;
  • 2.23 Ultimate Vacuum Degree: 10Pa;
  • 2.24 Equipment Weight: Approximately 1500Kg;
  • 2.25 Equipment Color: Light gray;
  • 2.26 Reference Dimensions of the Appearance: 1650×1950×2000mm (W×H×D), and the specific dimensions shall be subject to the actual product.
Chitherm 1000°C Hwf160-10nh Vacuum Atmosphere Tank Furnace Chitherm 1000°C Hwf160-10nh Vacuum Atmosphere Tank Furnace
3. General Technical Description
SUS310S Vertical Muffle Furnace Electric Vacuum Nitrogen Hydrogen Atmosphere 2
Figure 1 Schematic Diagram of the Equipment Structure
4. Delivery List
Item Note Qty.
Basic Components Furnace 1 SET
inspection certificate Certificate of major outsourced components 1 SET
Technical Documents Instructions, technical documents of the major outsourced parts, etc 1 SET
Key Components Heating Element 1 SET
Vacuum System 1 SET
Touch Screen 1 SET
Temperature Controller Azbil 1 SET
Thermocouple Type K 1 PCS
PLC 1 SET
Spare Parts SSR 1 PC
5. Facility Requirements
  • 1. Environmental Conditions: temp.: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance.
  • 2. N2 Conditions: 99.999% purity, working pressure: 0.2-0.4MPa, Max gas consumption 2-6 m3/h.
  • 3. H2 Conditions: working pressure: 0.2-0.4MPa, Max gas consumption 1-3m3/h.
  • 4. Water Conditions: clean, no corrosive water, working pressure 0.1-0.3MPa, 3-9L/min
  • 5. Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 15m3/h
  • 6. Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 kg/m2;
  • 7. Power Condition(TBD): capacity > 55kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
  • 8. Installation Site: 3000mm×2500mm×3000mm(D×W×H), with an installation area greater than 7.5m2.
Chitherm 1000°C Hwf160-10nh Vacuum Atmosphere Tank Furnace