Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Vacuum Muffle Furnace
Created with Pixso. Controlled Atmosphere Industrial Furnace Muffle Vacuum Dryer OEM

Controlled Atmosphere Industrial Furnace Muffle Vacuum Dryer OEM

Brand Name: Chitherm
Model Number: Hpf190-03n
MOQ: 1
Price: Negotiable
Delivery Time: Customized
Payment Terms: Customized
Detail Information
Place of Origin:
China
Range Of Applications:
Industrial
Type:
Electric Holding Furnace
Usage:
Steel Molding
Fuel:
Electric
Atmosphere:
Vacuum
Effective Dimensions:
500mm*700mm*550mm(W*H*D)
Max Vacuum Level:
≤50PA
Transport Package:
Wooden Packaging
Specification:
755mm*1680mm*950mm(W*H*D)
Trademark:
Chitherm
Origin:
China
HS Code:
8514101000
Supply Ability:
50 Sets/Year
Customization:
Available
Certification:
ISO
Place Style:
Horizontal
Packaging Details:
Customized
Supply Ability:
Customized
Highlight:

Atmosphere industrial furnace muffle

,

OEM industrial furnace muffle

,

OEM controlled atmosphere muffle furnace

Product Description
Controlled Atmosphere Industrial Furnace Muffle Vacuum Dryer OEM
Product Specifications
Attribute Value
Range of Applications Industrial
Type Electric Holding Furnace
Usage Steel Molding
Fuel Electric
Atmosphere Vacuum
Effective Dimensions 500mm*700mm*550mm(W*H*D)
Max Vacuum Level ≤50PA
Transport Package Wooden Packaging
Specification 755mm*1680mm*950mm(W*H*D)
Trademark Chitherm
Origin China
HS Code 8514101000
Supply Ability 50 Sets/Year
Customization Available
Certification ISO
Place Style Horizontal
Product Description

Chitherm Hpf190-03n Vacuum Dryer Electric Holding Furnace 755mm*1680mm*950mm W*H*D for Versatile Drying Applications

1. Typical Applications

Primarily used for drying, debinding, and curing of electronic components in vacuum or controlled atmosphere environments.

Controlled Atmosphere Industrial Furnace Muffle Vacuum Dryer OEM 0 Controlled Atmosphere Industrial Furnace Muffle Vacuum Dryer OEM 1
2. Parameter Characteristics
  • 2.1 Operating Temperature: RT~200°C
  • 2.2 Maximum Temperature: 250°C
  • 2.3 Furnace Chamber Material: SUS304 stainless steel
  • 2.4 Insulation Material: Ceramic fiber
  • 2.5 Chamber Dimensions: 500mm*700mm*550mm (W*H*D)
  • 2.6 Temperature Uniformity: Surface temperature uniformity of heating plates: within ±5°C (tested at 200°C constant temperature)
  • 2.7 Heating Elements: Aluminum heating plates
  • 2.8 Number of Heating Plates: 4
  • 2.9 Maximum Heating Power: 4*1.5kW
  • 2.10 Heating Rate: ≤5°C/min
  • 2.11 Temperature Control Element: Platinum resistance (PT100)
  • 2.12 Temperature Control Points: 4 points
  • 2.13 Temperature Control Method: Cycle zero-crossing control
  • 2.14 Centralized Control: Touch screen + PLC centralized control
  • 2.15 Temperature Control Accuracy: ±1°C
  • 2.16 Ultimate Vacuum: ≤50Pa
  • 2.17 Vacuum Pumping Time: ≤30 minutes (from atmospheric pressure to 0.1mbar)
  • 2.18 Chamber Pressure Resistance: 0.1~1mbar (operable under vacuum or atmospheric pressure)
  • 2.19 Vacuum Alarm: Triggers an alarm and shuts off the vacuum pump if the preset vacuum level is not achieved within the specified time
  • 2.20 Alarm Protections: Audible/visual alarms for over-temperature, motor overload, and phase reversal failure
  • 2.21 Noise Level: ≤63dB
  • 2.22 Exterior Finish: High-temperature spray coating, light gray
  • 2.23 Overall Dimensions (Reference): 755mm*1680mm*950mm (W*H*D)
3. Delivery Checklist
Category Name Main Contents Quantity
Basic Components Furnace Main Unit 1 unit
Inspection Certificates Certificates for key purchased components 1 set
Technical Documents User manual Technical documents for key purchased components, etc. 1 set
Key Components Heating Plates 4 pieces
Touch Screen 1 unit
Resistive Vacuum Gauge 1 unit
Resistive Gauge Tube 1 unit
Spare Parts Solid-State Relay (SSR) 1 piece
4. Equipment Normal Operating Conditions
  • 4.1 Environmental Conditions: Temperature 0~40°C, humidity ≤80% RH, no corrosive gases, no strong airflow disturbances
  • 4.2 Gas Supply Requirements:
    • High-purity nitrogen (process protective gas): Purity >99.999%, inlet pressure 0.1~0.2MPa
    • Dry, clean, oil-free compressed air (purge gas): Inlet pressure 0.4~0.8MPa
  • 4.3 Ventilation System: Non-contact connection to user's exhaust system, exhaust capacity >10m³/h
  • 4.4 Floor Requirements: Level surface, minimal vibration, load-bearing capacity >200kg/m²
  • 4.5 Power Supply: Capacity >8kVA, three-phase five-wire system, AC380V, 50Hz
  • 4.6 Installation Space: 2000mm*2000mm*3000mm (Depth*Width*Height), installation area >4m²